Oracle Sun 10000 Server

Oracle Sun 10000 Server Oracle Sun 10000 Server sun enterprise 10000 copy

REQUEST A PRICE QUOTE:

Name*

Phone

Details*



 

Processor
Number 4 to 64
Architecture 250, 336, 400, or 466 MHz UltraSPARC[tm]-II
Cache per processor Primary: 16-KB instruction, and 16-KB data on chip
Secondary: 4-MB external cache or 8-MB external cache (466 MHz module)
CPU interface 64-bit Ultra Port Architecture (UPA)
System Interconnect Gigaplane-XB interconnect, 12.8 GB/second throughput
Memory data bus: 576 bits
Data bus: 144 bits per board
CPU data bus: 144 bits
System Boards
Number of boards Maximum of 16 boards per Enterprise 10000 server; minimum configuration is one system board
CPU/Memory board Up to four processors and four banks of eight memory SIMMs on each system board
I/O Board Up to four SBus cards or two PCI cards on each system board
Control Board Up to two boards per Enterprise 10000 server; controls the system JTAG, clock, fan, power, serial interface, and Ethernet interface functions
Main Memory
2-GB to 64-GB memory capacity per system

256-MB and 1-GB memory expansion options (each a group of 8 SIMMs)

Up to four memory expansion options per system board

Standard Interfaces
Ethernet One twisted-pair ethernet (10BASE-T) port (RJ-45) per Control Board; for use only between the Control Board(s) and the System Service Processor(s)
PCI Two slots per PCI I/O module mounted on the System Board; 32-bit or 64-bit data bus width, 33- or 66-MHz, short cards (6.5-inch)
SBus Four slots per SBus I/O module mounted on the System Board; 32-bit or 64-bit data bus width, 25 MHz
Internal Mass Storage
Disk Array/Tray Maximum of two Sun StorEdge D1000 arrays (capacity up to 2 TB)
or

Maximum of 16 UniPack disks and 4 UniPack trays

or
a combination of both
Power Supplies
N+1 system redundancy
Universal 220 VAC-to-48 DC volt
up to 2 AC power sequencers
Environment
AC input1 200 – 240 VAC, 47 – 63 Hz, 24 A (max)
Input power 13,456 W
Heat output 52,000 BTU/hr
Temperature Optimal: 21° C to 23° C (70° F to 74° F)
Operating: 10° C to 32° C (50° F to 90° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity2 Optimal: 45% to 50% relative humidity, noncondensing
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: Up to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Number of cords 5 (max)
1Per line cord; up to five redundant line cords
2Operating temperature ramp rate not to exceed 68° F (20° C) per hour, humidity ramp rate not to exceed 30% relative humidity per hour. Nonoperating temperature ramp rate not to exceed 59° F (15° C) per hour, humidity ramp rate not to exceed 20% relative humidity per hour.
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, CUL CAN/CSA 22:2 M950, TUV EN60950
RFI/EMI FCC Class A, EN50021-1 Class A
Immunity EN50082-1
Dimensions and Weights
Height 177.8 cm (70 in.)
200 cm (78.75 in.) shipping
Width 97.2 cm (38.25 in.)
123.8 cm (48.75 in.) shipping
Depth 126.8 cm (49.9 in.)
155.6 cm (61.25 in.) shipping
Weight 909 kg (2000 lb.) approximate
1000 kg (2200 lb.) approximate shipping
Power Cord 4.6 m (15 ft.)
Backplanes
Option # Top Level
Part #
Manufacturing
Part #
Description
n/a n/a 501-4348 Centerplane
n/a n/a 501-4346 Centerplane Support Board
n/a n/a 565-1695 Centerplane Power Module Repair Kit
Communication
Option # Top Level
Part #
Manufacturing
Part #
Description
X1071A 605-1636 370-3878 HIPPI/P 1.1
X1080A 605-1649 370-4273 Enterprise System Interface (ESI/P)
X1157A 605-1623 501-3028 SunATM-155/MFiber PCI 4.0
X1012A 605-1319 501-2603 SunLink ISDN
X1070A 605-1631 370-3878 HIPPI/P 1.0
X1073A 595-4344 370-2868 SBus Cluster Interconnect Card (SCI)
X1142A 605-1610 370-3142 FDDI/S SAS 6.0
X1143A 605-1609 370-3143 FDDI/S DAS 6.0
X1144A 605-1616 501-1932 Token Ring Interface/SBus (TRI/S) 4.0
X1145A 605-1612 501-1725 High Speed Serial Interface/SBus (HSI/S) 3.0
X1146A 595-5036 501-1931 SBus Serial Parallel Controller (SPC/S) 3.0
X1147A 605-1620 501-2794 SunATM-155/MFiber 4.0
X1148A 605-1621 501-2795 SunATM-155/UTP 4.0
X1149A 605-1622 501-2864 SunATM-622/MFiber 4.0
X1158A 605-1624 501-3027 SunATM-155/UTP PCI 4.0
X1159A 605-1625 501-3029 SunATM-622/MFiber PCI 4.0
X2144A 605-1645 501-1932 Token Ring Interface/SBus (TRI/S) 5.0
CPU Module
Option # Top Level
Part #
Manufacturing
Part #
Description
X2530A 595-4343 501-4178 250MHz UltraSPARC II
X2550A 595-4410 501-4836 250MHz UltraSPARC II
X2560A 596-2325 501-4363 333MHz UltraSPARC II
X2570A 595-5065 501-5425 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
n/a n/a 501-4995 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
X2580A 596-2567 501-5661 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
501-5762 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
2580A
(before April 2001)
596-2556 501-5814 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-5815 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6009 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
Mirrored Tag SRAM
501-5838 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
501-6008 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
2580A
(after April 2001)
596-2556 501-6619 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6624 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
2590A 596-3110 501-6620 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-6623 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
n/a n/a 501-5798 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-5816 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
Disks
Option # Top Level
Part #
Description Assembly # Manufacturing
Part #
SG-ARY154A-72R4 596-2984 StorEdge D1000 12-Slot Rackmount
72GB (4 × 18.2GB) 10000 RPM
540-4178

A1000/D1000 FRU
w/ 1″ Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269

390-0002
390-0006
390-0038
390-0043
390-0048
390-0066
390-0085
SG-ARY173A-145R4 596-2985 StorEdge D1000 12-Slot Rackmount
145GB (4 × 36.4GB) 10000 RPM
540-4520

A1000/D1000 FRU
w/ 1″ Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269

390-0050
390-0051
390-0052
390-0065
390-0069
390-0109
390-0110
390-0111
SG-ARY154A-218R4 596-2986 StorEdge D1000 12-Slot Rackmount
218GB (12 × 18.2GB) 10000 RPM
540-4178

A1000/D1000 FRU
w/ 1″ Bracket 540-3024
w/ Plate 340-4288

390-0002
390-0006
390-0038
390-0043
390-0048
390-0066
390-0085
SG-ARY173A-436R4 596-2987 StorEdge D1000 12-Slot Rackmount
436GB (12 × 36.4GB) 10000 RPM
540-4520

A1000/D1000 FRU
w/ 1″ Bracket 540-3024
w/ Plate 340-4288
or Plate 340-6640

390-0050
390-0051
390-0052
390-0065
390-0069
390-0109
390-0110
390-0111
SG-DSK010C-18G 599-2326 StorEdge UniPack – 18.2GB 10000 RPM 540-4305
Disk Drive Assembly
390-0002
390-0038
390-0060
X9645A 595-5120 StorEdge UniPack tray n/a 540-3564
Ethernet
Option # Top Level
Part #
Manufacturing
Part #
Description
X1044A 605-1591 375-0002 Gigabit Ethernet (GBE/P) 1.0
X1045A 605-1592 375-0003 Gigabit Ethernet (GBE/S) 1.0
X1049A 605-1597 501-5443 Sun Quad FastEthernet (SQFE/S) 2.0
X1059A 605-1535 501-2919 SunFastEthernet Adapter 2.0 (Colossus Lite)
X1140A 605-1602 501-4375 Gigabit Ethernet (GBE/S) 2.0
X1141A 605-1601 501-4373 Gigabit Ethernet (GBE/P) 2.0
X1151A 595-5773 501-5524 Sun GigaSwift Ethernet MMF
X2721A 595-4945 370-3795 SuperStack II Entry Hub
X2722A 595-5205 370-3795 SuperStack II Entry Hub
X3151A 595-5773 501-5524 Sun GigaSwift Ethernet MMF
Fibre Channel
Option # Top Level
Part #
Manufacturing
Part #
Description
X6727A 595-5853 375-3030 PCI Dual FC Network Adapter+
X6757A 595-5943 375-3048 SBus Dual FC Network Adapter
SG-XPCI1FC-QF2 * 595-6425 375-3102 2GB PCI Single FC Network Adapter
SG-XPCI2FC-QF2 * 595-6426 375-3108 2GB PCI Dual FC Network Adapter
SG-XPCI1FC-QL2 594-2466 375-3383 2GB PCI-X Single FC Host Adapter, RoHS:Y
X1057A 595-3213 501-2553 Fibre Channel Host Adapter (FC25/S)
X6730A 595-4303 540-2989
Oracle Sun 10000 Server Oracle Sun 10000 Server bullet 501-5266
FC-AL SBus Host Adapter (FC100/S)
X6746A 595-5816 540-4372 StorEdge Network FC Switch-8
X6767A* 595-6425 375-3102 2GB PCI Single FC Network Adapter
X6768A* 595-6426 375-3108 2GB PCI Dual FC Network Adapter
X6799A 595-5830 375-3019 PCI Single FC Host Adapter
* X6767A changed to SG-XPCI1FC-QF2 and X6768A changed to SG-XPCI2FC-QF2 in July 2003
I/O Boards
Option # Top Level
Part #
Manufacturing
Part #
Description Previous
Part #
2730A 596-2148 501-4478 SBus I/O Board 501-4349
2731A 596-2294 501-4830 PCI I/O Board 500-4779
501-4777
501-4778
PCI I/O Riser Board (3.3V)
PCI I/O Riser Board (5V)
n/a
n/a
Memory
Option # Top Level
Part #
Manufacturing
Part #
Option Description
X7022A 595-3869 501-2653 (32MB) 256 MB (8 × 32MB DIMMS)
X7023A 595-3870 501-2654 (128MB) 1 GB (8 × 128MB DIMMS)
X7025A 595-4625 501-4776 E10000 Memory Board
Power – DC
Option # Top Level
Part #
Manufacturing
Part #
Description
X9685A 595-4628 300-1430 Sun Type A135 2000 Watt Power Supply
Power – AC
Option # Top Level
Part #
Manufacturing
Part #
Description
X3875A 595-4624 540-3441 AC Input Module
n/a AC Input Module Power Requirements
9620A 596-2453 300-1403 2nd AC Power Sequencer 230V
(standard on newer models)
n/a AC Power Sequencer Power Requirements
X9681A 595-4627 540-3440 Remote Power Control Module
SCSI
Option # Top Level
Part #
Manufacturing
Part #
Description
X1018A 605-1568 501-2739 Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift)
X1052A 595-2731 501-1902 Fast Differential SCSI-2/Buffered Ethernet Card (DSBE/S)
X1053A 595-2724 501-2015 Fast SCSI-2/Buffered Ethernet Card (FSBE/S)
X1062A 595-3257 370-1704 Differential Fast/Wide SCSI-2 Host Adapter (DWIS/S)
X1063A 595-3258 370-1703 Single-Ended Fast/Wide SCSI-2 Host Adapter (SWIS/S)
X1065A 595-4187 370-2443 Differential Ultra/Wide SCSI Host Adapter (UDWIS/S)
X2222A 595-5624 501-5727 Dual Ultra-2 SCSI/Dual FastEthernet PCI Adapter
System Board
Option # Top Level
Part #
Manufacturing
Part #
Description
2761A 596-2388 501-5693 E10000 System Board
X2720A 595-4619 501-4345 E10000 Control Board
X2721A 595-4945 501-4345 E10000 Control Board
X2722A 595-5205 501-5494 E10000 Control Board
X2760A 595-4621 501-4903 E10000 System Board
X2761A 595-4947 501-5240 E10000 System Board
n/a n/a 501-6336 E10000 System Board
n/a n/a 501-4347 E10000 System Board
n/a n/a 501-4786 E10000 System Board
n/a n/a 501-4839 E10000 Control Board
n/a n/a 501-5278 E10000 System Board
n/a n/a 501-5279 E10000 System Board
System Service Processor (SSP)
Option # Manufacturing
Part #
Description
X2750A 603-2997 E10000 SSP (SPARCstation 5)
X2751A 600-5471 E10000 SSP (Ultra 5)
X2753A 600-5931 E10000 SSP (Ultra 5+)
X2754A 600-6466 E10000 SSP (Ultra 5+)
X2755A 600-7415 E10000 SSP (Enterprise 250)
X2757A 602-2438 E10000 SSP (Sun Fire V120)

Industry Leading Quality, Support and Integrity

Quality Inspection Checklist
Before it leaves our facility, every used and refurbished item is thoroughly inspected by our certified technicians and undergoes our exclusive Quality Inspection Checklist to ensure 100% satisfaction guarantee.

Greentec Systems is a leading provider
For server, networking and storage equipment. We have an extensive array of inventory of IBM Servers & Storage, Sun Servers & Storage, Cisco Networking (Switches, Routers, Security), and NetApp Storage (disk shelves, disk drives, Filers, NearStore, NetCache). If you don’t see the item or product you require please contact us.

Have this equipment to sell?
Depending on the age and condition of the equipment, there is a very good likelihood that we will be able to offer you cash or trade-in credit for other IT hardware. If the equipment is very old we can also assist you with properly decommissioning that gear in the most environmentally friendly way possible.

Questions?
For more information please contact 888.333.7388, or fill out the quote from above. We’d love to hear from you.

Request Quote
Greentec Systems We geek out helping you with your IT infrastructure.
Request a quote or product information
Send